Product Catalog

Product Construction
Conductor:
  • 22 - 24 AWG stranded tinned copper wire conductors per ASTM B-33
Insulation:
  • Color coded foam FEP 200°C
Shield:
  • Each pair 100% coverage Polyester/aluminum foil shield, 25% overlap, foil facing in with stranded tinned copper drain wire
Jacket:
  • PVDF Plenum Rated
  • Documentation marker tape for identification
  • Temperature: -20°C to +150°C
  • Voltage: 300 Volts
1 - 4 of 4 | Results Per Page | View | Unit of Measure
1 

Part #

Conductor Size

Strands

No. of Pairs

Insulation Thickness

Jacket Thickness

Nominal O.D.

9859 N/A 22 AWG N/A (7 x 30) Tin Copper Wire N/A 1 N/A 0.015 in. N/A 0.010 in. N/A 0.200 in.
9867 N/A 24 AWG N/A (7 x 32) Tin Copper Wire N/A 2 N/A 0.015 in. N/A 0.010 in. N/A 0.244 in.
9868 N/A 24 AWG N/A (7 x 32) Tin Copper Wire N/A 3 N/A 0.015 in. N/A 0.010 in. N/A 0.261 in.
9869 N/A 24 AWG N/A (7 x 32) Tin Copper Wire N/A 4 N/A 0.015 in. N/A 0.012 in. N/A 0.294 in.
1 - 4 of 4 | Results Per Page | View | Unit of Measure