Product Catalog

Product Construction
Conductor:
  • 22 thru 12 AWG annealed stranded tinned copper wire per ASTM B-33
  • Insulation:
    • Color coded PVC insulation
    Shield:
    • Polyester/Aluminum foil shield, 100% coverage, with stranded tinned copper wire drain
    • Stranded tinned copper wire drain
    Jacket:
    • Chrome gray PVC
    • Temperature: -20°C to +105°C
    • Voltage: 300 volts
    1 - 11 of 11 | Results Per Page | View | Unit of Measure
    1 

    Part #

    Conductor Size

    Strands

    No. of Conductors

    Insulation Thickness

    Shield

    Jacket Thickness

    Nominal O.D.

    5010 N/A 22 AWG N/A (7 x 30) Tin Copper Wire N/A 2 N/A 0.016 in. N/A Polyester/Aluminum foil shield, 25% overlap and stranded tinned copper wire drain N/A 0.038 in. N/A 0.202 in.
    5011 N/A 20 AWG N/A (10 x 30) Tin Copper Wire N/A 2 N/A 0.016 in. N/A Polyester/Aluminum foil shield, 25% overlap and stranded tinned copper wire drain N/A 0.038 in. N/A 0.216 in.
    5012 N/A 18 AWG N/A (16 x 30) Tin Copper Wire N/A 2 N/A 0.016 in. N/A Polyester/Aluminum foil shield, 25% overlap and stranded tinned copper wire drain N/A 0.038 in. N/A 0.236 in.
    5013 N/A 16 AWG N/A (26 x 30) Tin Copper Wire N/A 2 N/A 0.016 in. N/A Polyester/Aluminum foil shield, 25% overlap and stranded tinned copper wire drain N/A 0.038 in. N/A 0.262 in.
    5014 N/A 14 AWG N/A (41 x 30) Tin Copper Wire N/A 2 N/A 0.020 in. N/A Polyester/Aluminum foil shield, 25% overlap and stranded tinned copper wire drain N/A 0.043 in. N/A 0.314 in.
    5015 N/A 12 AWG N/A (65 x 30) Tin Copper Wire N/A 2 N/A 0.032 in. N/A Polyester/Aluminum foil shield, 25% overlap and stranded tinned copper wire drain N/A 0.053 in. N/A 0.416 in.
    5030 N/A 22 AWG N/A (7 x 30) Tin Copper Wire N/A 3 N/A 0.016 in. N/A Polyester/Aluminum foil shield, 25% overlap and stranded tinned copper wire drain N/A 0.038 in. N/A 0.212 in.
    5031 N/A 20 AWG N/A (10 x 30) Tin Copper Wire N/A 3 N/A 0.016 in. N/A Polyester/Aluminum foil shield, 25% overlap and stranded tinned copper wire drain N/A 0.038 in. N/A 0.227 in.
    5032 N/A 18 AWG N/A (16 x 30) Tin Copper Wire N/A 3 N/A 0.016 in. N/A Polyester/Aluminum foil shield, 25% overlap and stranded tinned copper wire drain N/A 0.038 in. N/A 0.248 in.
    5033 N/A 16 AWG N/A (26 x 30) Tin Copper Wire N/A 3 N/A 0.016 in. N/A Polyester/Aluminum foil shield, 25% overlap and stranded tinned copper wire drain N/A 0.038 in. N/A 0.276 in.
    5034 N/A 14 AWG N/A (41 x 30) Tin Copper Wire N/A 3 N/A 0.020 in. N/A Polyester/Aluminum foil shield, 25% overlap and stranded tinned copper wire drain N/A 0.043 in. N/A 0.331 in.
    1 - 11 of 11 | Results Per Page | View | Unit of Measure
    1